HVAC

UnitSizeFiltersManufacturerModelYearSerialThermostatService AreasNotes
RTU #15 ton(2) 16x25x2Bryant???Creative ArtsCreative Arts, Bathrooms, Conf Rooms
RTU #25 ton(2) 16x25x2Carrier48HJD006-54120082408G20399Front Hallway3D Fab, Lobby, Electronics
RTU #3? ton(4) 20x20x2Lennox?2017?Interactive ClassroomInteractive Classroom
RTU #45 ton(2) 20x30x2Trane???Open WorkroomOpen Workroom, Purple ClassroomReplaced in May 2015, need to get full info
RTU #55 ton(2) 16x25x2Bryant???Workshop, north pillarWorkshop
RTU #65 ton(2) 16x25x2Bryant???Lecture RoomWorkshop, Lecture RoomAll vents to workshop are closed
RTU #75 ton(2) 16x25x2Carrier580FPV060074AB20073707G10259Workshop, south pillarWorkshop
RTU #8? ton(4) 20x20x2Lennox???Workshop, south pillarWorkshop
RTU #910 ton(4) 20x24x2LennoxZGB120S4BS1Y20205620D08932WoodworkingBreak room, woodworking, metalworking

We currently have only one split unit, this unit services the server room only.

UnitTypeSizeFiltersManufacturerModelYearSerialNotes
SS 2Condenser5 tonn/aGoodmanCRT162006060622933
SS 2AHU5 ton(1) 20x20x1CarrierunknownunknownunknownLocated inside the building, above the interactive classroom.
Unit Size Filters Manufacturer Model Year Serial Thermostat Service Areas Notes
RTU #1 7.5 ton 4 - 16x20x2 Carrier 48TMD008-A-501 2003 0303G30643 ? Office 208/230V 3 Phase Gas Pack
RTU #2 10 ton Trane YSC120AELA 2004 406100302L ? Office 208/230V 3 Phase Gas Pack
RTU #3 10 ton Trane YSC120AELA 2005 ? ? Office 208/230V 3 Phase Gas Pack
RTU #4 5 ton 1 - 20x24x1 Carrier 48TJD006-511GA 2005 3899G21027 Office 208/230V 3 Phase Gas Pack
RTU #5 7.5 ton 4 - 20x24x2 Allied ZGB092S4BS1Y Installed
new 2018
5618G04125 Workshop, north pillar Workshop 208/230V 3 Phase Gas Pack
RTU #6 7.5 ton 4 - 20x24x2 Allied ZGB092S4BS1Y Installed
new 2018
5618G06452 Workshop, south pillar Workshop 208/230V 3 Phase Gas Pack
RTU #7 15 ton 6 - 24x24x2 Allied KCB180S4BN1G Installed
new 2018
5618E04674 Workshop, south side of north pillar Workshop 480V 3 Phase
A/C only
  • Serial numbers for RTU #5 and RTU #6 might be reversed.
  • All RTUs are heat and A/C except RTU #7, which is A/C only

New split unit installed 2018, this unit services the server room only. All table data below are just placeholders

UnitTypeSizeFiltersManufacturerModelYearSerialNotes
SS 2Condenser2 tonn/aGoodmanCRT162018060622933
SS 2AHU2 ton(1) 20x20x1Carrierunknown2018unknownLocated inside the building, above the interactive classroom.

Carrier 5T unit RTU#4: File:HVAC_Carrier_48TJD.pdf - manual

Allied 7.5T units RTU#5 and #6, Suite 102

File:Install ZSeries ZC 7.5 12.5.pdf - Installation manual from two new RTU’s over Suite 102. Installed by the landlord October 2018

File:Zseries-75ton-installation-notes.jpg - Installation notes and start-up test from the install of the Suite 102 ZSeries 7.5 ton unit.

File:Zseries-75ton-installation-notes-2.jpg - Installation notes and start-up test from the install of the other Suite 102 ZSeries 7.5 ton unit.

Allied 15T unit RTU#7, Suite 102

File:HVAC_KSeries_KGA_15_25.pdf - Installation manual from new 15T RTU over Suite 102. Air Conditioning only. Installed by the landlord October 2018

File:HVAC_15_Ton.jpg - Installation notes and start-up test

Migrated from the legacy DMS wiki: original page