Electrical Buildout

This information may be outdated.
If you feel this is in error, please remove the {{outdated}} template.

The Board of Directors have authorized up to $1,000 for the electrical build out. Our current plan includes adding 3x 20A 110V, 3x 30A 220V and 1x 50A 220V circuits to the warehouse.

Before any other work can be performed, the main electrical panel needs to be replaced. We have contracted with a master electrician who will be replacing our current panel with a new single phase 200A Square D (QO style) panel. This work will require power to be turned off for 2 to 4 hours, likely during the day.

The panel has already been purchased and is awaiting installation, which is planned for Thursday, May 10th.

In no particular order, the following circuits will be installed:

  • 2x 20A 110V circuits along the west wall, similar to the setup on the east wall
  • 1x 20A 110V circuit overhead, running east to west, roughly in line with the bay door (for retractable extension cords)
  • 1x 30A 220V circuit for the cabinet saw, along the north wall on the woodworking side
  • 1x 30A 220V circuit for future use, also along the north wall on the woodworking side
  • 1x 30A 220V circuit for the kiln, along the north wall on the metalworking side
  • 1x 50A 220V circuit for the welder and electric cars, along the west wall

Additional steps to take have not yet been determined.

The warehouse is used for much more than just storage, we have tools for woodworking, metalworking, welding, vehicle maintenance/mad-sciencery, and a kiln.

Minimum requirements:

  • 2x 20amp 110v circuits
  • 2-outlet or 4-outlet boxes every 5 feet, on alternating circuits
  • 1x 220v circuit, with outlet location to be decided

Ideal:

  • 2x 20amp 110v circuits
  • 4-outlet boxes every 5 feet, on alternating circuits
  • 2x 220v circuits, with outlet locations to be decided

Minimum requirements:

  • 1x 20amp 110v circuit
  • 1x 4-outlet box on each side of the storage area

Ideal:

  • 1x 20amp 110v circuit
  • 1x 4-outlet box on each side of the storage area
  • 1x 220v circuit, with an outlet on each side of the storage area

Minimum requirements:

  • 1x 20amp 110v circuit
  • 2x 4-outlet boxes
  • 1x 220v circuit, with outlet location to be decided

Ideal:

  • 2x 20amp 110v circuits
  • 2-outlet or 4-outlet boxes every 5 feet, on alternating circuits
  • 2x 220v circuits, with outlet locations to be decided

No minimum requirements at this time.

Minimum requirements:

  • 2x retractable overhead extension cords, location to be decided

Ideal:

  • 2x 20amp 110v circuits
  • 4x retractable overhead extension cords